Core Product Summary
The Molex SST-PB3-VME-2-E is a dual-channel PROFIBUS network interface card designed for VMEbus systems. It provides two independent PROFIBUS interfaces, each controlled by its own processor, enabling simultaneous DP master, DP slave, and FDL layer-2 messaging on PROFIBUS DP-V0 networks.
Each channel supports all standard PROFIBUS baud rates from 9.6 kbps to 12 Mbps and interfaces with the host through shared dual-ported memory using VME A24 and A16 addressing with 16-bit data transfers. The card is a double-height (6U) VME module that draws power from the +5 V backplane supply and uses a standard 9-pin D-sub female connector per channel.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | PROFIBUS network interface card |
| Channels | 2 independent channels |
| Protocol | PROFIBUS DP-V0 master (Class 1 & Class 2), DP-V0 slave, FDL layer 2 |
| Baud rates | 9.6 kbps, 19.2 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps |
| Bus interface | VMEbus, VME64-compliant (VITA 1.1 1997) |
| Data transfers | VME D16 with A24 (standard) and A16 (short I/O) addressing |
| Processor | ColdFIRE 5272 (independent per channel) |
| Host memory window | Minimum 256 KB dual-ported memory window per channel |
| Network connector | 9-pin D-sub female (one per channel) |
| Isolation | 1000 V |
| Supply voltage | +5 V from VMEbus |
| Typical current (2-channel) | 1400 mA |
| Operating temperature | 0 °C to +60 °C |
| Storage temperature | –40 °C to +85 °C |
| Humidity | 5 % to 90 % non-condensing |
| Form factor | Double-height (6U) VME module |
| Approvals | CE |
Detailed Product Overview
The SST-PB3-VME-2-E belongs to the Molex SST PB3 family of industrial network interface cards. It is engineered to connect VME-based programmable controllers, motion controllers, and computers to PROFIBUS DP-V0 and FDL networks.
Each of the two channels operates with a dedicated processor and local resources. This architecture ensures that an application running on one channel does not share memory or processor capacity with the other channel, allowing independent operation and simultaneous master/slave/FDL modes on the same or separate network segments.
Communication with the host occurs through a shared dual-ported memory interface. The card supports 16-bit data transfers and can be mapped into both standard (A24) and short I/O (A16) address spaces. Address selection is performed via onboard DIP switches. Firmware is downloadable and determines the exact application-level behavior of each channel.
Front-panel LEDs provide status indication for system fail, watchdog timeout, system status, and communications activity on each channel. A serial port is available for configuration and diagnostic access. The card is intended for installation in a standard VME64 chassis that supplies +5 V and provides the required address and data paths.

SST-PB3-VME-2-E

SST-PB3-VME-2-E
Dimensions, Mounting & Connection Notes
The card is a double-height (6U) VME module. It occupies one standard VME slot and connects to the backplane for power and bus signals.
Each channel is fitted with a 9-pin D-sub female PROFIBUS connector on the front panel. Recommended cabling follows standard PROFIBUS specifications (for example, Belden 3079A or equivalent). Proper bus termination must be applied at the network ends.
A chassis ground connection is provided. The card contains static-sensitive components; appropriate ESD handling procedures must be observed during installation.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host bus | VMEbus, VME64-compliant (VITA 1.1 1997) | Must support D16 transfers and A24/A16 addressing |
| Chassis / form factor | Double-height (6U) VME slot | Requires one full 6U slot |
| Power | +5 V from VME backplane | Typical draw 1400 mA for the two-channel card |
| Memory mapping | Minimum 256 KB dual-ported window per channel | Window location set by DIP switch and software |
| Network connection | 9-pin D-sub female connector per channel | Standard PROFIBUS cabling required |
| Firmware | Downloadable application firmware modules | Must be loaded for operational use |
| Software interface | DLL and OPC DA | Host application development supported via documented memory interface |
FAQ
What is the Molex SST-PB3-VME-2-E?
It is a dual-channel PROFIBUS network interface card for VMEbus systems that supports simultaneous DP master, DP slave, and FDL layer-2 operation on each channel.
How many independent PROFIBUS channels does it provide?
Two independent channels, each with its own processor and resources.
What PROFIBUS baud rates are supported?
All standard rates from 9.6 kbps to 12 Mbps: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, and 12M baud.
What VME addressing modes does the card support?
It supports 16-bit (D16) transfers using both A24 standard and A16 short I/O address spaces.
What power supply does the card require?
+5 V from the VMEbus backplane. Typical current consumption for the two-channel version is 1400 mA.
What form factor is used?
Double-height (6U) VME module that occupies one full slot.
What connectors are used for the PROFIBUS networks?
One 9-pin D-sub female connector per channel.