National Instruments SCXI-1338 Current Input High-Voltage Terminal Block

The National Instruments SCXI-1338 is a specialized, front-mount current input and high-voltage terminal block designed to interface 0–20 mA or 4–20 mA industrial current loops with compatible National Instruments isolated analog input modules, such as the SCXI-1120, SCXI-1121, and SCXI-1125. Housed in a fully shielded metal enclosure, the unit integrates a precision 249 Ω, 0.1% shunt resistor across each of its input channels, converting incoming current signals into proportional voltage measurements that the host module can accurately acquire.

Categories: , , , , SKU: SCXI-1338 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The National Instruments SCXI-1338 is a specialized, front-mount current input and high-voltage terminal block designed to interface 0–20 mA or 4–20 mA industrial current loops with compatible National Instruments isolated analog input modules, such as the SCXI-1120, SCXI-1121, and SCXI-1125. Housed in a fully shielded metal enclosure, the unit integrates a precision 249 Ω, 0.1% shunt resistor across each of its input channels, converting incoming current signals into proportional voltage measurements that the host module can accurately acquire.

The terminal block features 18 screw terminals in total, comprising eight differential signal pairs and dedicated safety earth-ground connections. Engineered for demanding industrial environments, the SCXI-1338 supports maximum working voltages of up to 300 Vrms or \pm 300 VDC channel-to-channel and channel-to-ground. It accommodates standard copper wire gauges from 26 up to 16 AWG and mounts directly to the front of target SCXI modules using dual captive thumbscrews.

 

Key Technical Specifications

Specification Value / Detail
Product Type Current Input, High-Voltage Front-Mount Terminal Block
Total Screw Terminals 18 terminals (8 signal pairs / 16 signal terminals, plus safety ground pair)
Shunt Resistor (Per Channel) 249 Ω, 0.1%, 10 ppm, 1/4 W precision resistor
Maximum Input Current \pm 20 mA
Maximum Working Voltage 300 Vrms or \pm 300 VDC (channel-to-channel and channel-to-ground)
Supported Wire Gauge 26 to 16 AWG copper wire
Enclosure & Shielding Fully shielded metallic housing with integrated cable strain-relief bar
Mounting Method Front-mount with dual captive thumbscrews

 

Detailed Product Overview

The National Instruments SCXI-1338 acts as a dedicated physical adapter for acquiring industrial current signals within modular SCXI instrumentation setups. Because standard isolated analog input modules natively measure voltage, monitoring 4–20 mA or 0–20 mA current loops from transmitters, flow meters, and pressure transducers requires precise shunt resistor conversion. The SCXI-1338 solves this by incorporating high-accuracy 249 Ω precision resistors across every channel, translating current loops into accurate voltage drops that modules like the SCXI-1125 can safely process.

The unit is built inside a fully enclosed metal shell that mitigates electromagnetic interference (EMI) and external noise. By combining low-level current conditioning with high-voltage isolation boundaries (up to 300 Vrms working voltage), the terminal block enables safe data collection in heavy industrial and process control environments. Integrated mechanical strain relief secures incoming multi-conductor cables to protect individual screw terminal connections from vibration-induced fatigue.

SCXI-1338

SCXI-1338

SCXI-1338

SCXI-1338

Engineering Selection Highlights

  • Built-In Precision Shunt Resistors: Features factory-installed 249 Ω, 0.1% tolerance resistors on every channel to accurately convert 0–20 mA or 4–20 mA current inputs into readable voltage signals.
  • High-Voltage Working Isolation: Rated for up to 300 Vrms or \pm 300 VDC working voltage between channels and ground, maintaining safety in mixed-signal industrial systems.
  • Shielded Termination Structure: Enclosed in a protective metal housing that reduces electrical noise pickup for sensitive loop-powered instrumentation.
  • Integrated Earth-Ground Provision: Includes dedicated grounding terminals to tie shield drains and reference lines directly to the SCXI chassis ground.
  • Secure Mechanical Retention: Mounts tightly to the front panel of compatible isolation modules via integrated thumb screws, supported by a built-in cable strain-relief bar.

 

Dimensions, Mounting & Connection Notes

  • Physical Dimensions: 17.78 cm \times 7.94 cm \times 3.05 cm (7.0 in. \times 3.125 in. \times 1.2 in.)
  • Weight: Approximately 200 g (7 oz)
  • Mounting Procedure: Align the rear connector matrix with the module’s front header and secure the assembly by tightening the top and bottom thumbscrews.
  • Strain Relief Management: Clamp the outer sheath of the incoming multi-core cable underneath the strain-relief bar to isolate terminal screws from pulling tension.
  • Operating Limits: Designed for indoor use under Pollution Degree 2 conditions within a 0 °C to 50 °C temperature range.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Compatible Modules NI SCXI-1120, SCXI-1120D, SCXI-1125, SCXI-1126 Mounts directly to the front pin connector interface of these specific analog input modules.
Chassis Architecture National Instruments SCXI Chassis Requires installation in a compliant, properly grounded SCXI enclosure.
Field Conductor Size 26 to 16 AWG copper wire Strip wire ends cleanly to prevent stray strands from bridging adjacent screw terminals.

 

FAQ

What is the NI SCXI-1338?

The NI SCXI-1338 is a shielded front-mount terminal block equipped with built-in precision shunt resistors designed to convert and measure industrial current loop signals (0–20 mA / 4–20 mA) using SCXI isolation modules.

Which modules are compatible with the SCXI-1338?

It is compatible with National Instruments analog input and signal conditioning modules including the SCXI-1120, SCXI-1120D, SCXI-1125, and SCXI-1126.

How does the terminal block convert current to voltage?

It contains a 249 Ω, 0.1% precision resistor across each input channel, which converts incoming loop currents into proportional voltage drops for the host module to measure.

What are the maximum voltage and current ratings?

The module handles input currents up to \pm 20 mA and provides a maximum working voltage rating of 300 Vrms or \pm 300 VDC channel-to-channel and channel-to-ground.

How is the terminal block secured to the measurement system?

It mounts directly onto the front face of the target SCXI module and is secured in place using dual captive thumbscrews.

 

Verification & Troubleshooting Notes

  • Current Loop Verification: If signal readings read zero or flatline, verify loop power continuity and check that external current transmitters are actively driving current through the correct terminal pairs.
  • Resistor Integrity Check: In the event of channel scaling inaccuracies, disconnect field wiring and measure resistance across the channel screw terminals to verify the internal 249 Ω shunt resistor is uncompromised.
  • Grounding Continuity: Ensure the internal ground connections and shielding housing make firm mechanical contact with the SCXI module frame to prevent common-mode noise interference on low-level loops.