Description
Core Product Summary
The NI PXI-6052E is a multifunction data acquisition (DAQ) module in National Instruments’ E Series hardware family. It combines analog input, analog output, digital I/O, and counter/timer functionality in a PXI-based measurement system. The module supports 16-bit analog input conversion at a maximum guaranteed sampling rate of 333 kS/s, making it suitable for applications that require programmable voltage measurement and signal generation.
The analog input subsystem supports 16 single-ended or 8 differential channels, with software-selectable input ranges. Two 16-bit analog output channels support voltage generation, while eight digital I/O channels provide 5 V TTL/CMOS-compatible digital signaling. Two 24-bit up/down counter/timers and a frequency scaler provide additional timing functions. Integration planning should account for the PXI chassis, the module’s 68-pin male SCSI-II-type I/O connector, the applicable driver environment, and the signal-conditioning requirements of the connected equipment.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | PXI-6052E |
| Product family | E Series data acquisition |
| Hardware type | PXI multifunction I/O module |
| Analog input resolution | 16 bits |
| Analog input channels | 16 single-ended or 8 differential |
| Maximum analog input sampling rate | 333 kS/s |
| Analog input coupling | DC |
| Analog input voltage ranges | Software-selectable bipolar and unipolar ranges |
| Analog output channels | 2 voltage outputs |
| Analog output resolution | 16 bits |
| Maximum analog output update rate | 333 kS/s |
| Analog output ranges | ±10 V, 0–10 V, ±AO EXT REF, or 0 V to AO EXT REF |
| Digital I/O | 8 input/output channels |
| Digital logic compatibility | 5 V TTL/CMOS |
| Counter/timers | 2 up/down counter/timers, 24-bit resolution |
| Frequency scaler | 1, 4-bit resolution |
| Counter/timer maximum external source frequency | 20 MHz |
| PXI power requirement | +5 VDC ±5%, 1.3 A |
| I/O connector | 68-pin male SCSI-II type |
| Dimensions, excluding connectors | 160 × 100 mm |
| Weight | 206 g |
| Operating temperature | 0 to 55 °C |
| Operating relative humidity | 10–90%, noncondensing |
| Maximum operating altitude | 2,000 m |
Detailed Product Overview
Analog Input and Measurement
The PXI-6052E provides a multiplexed analog input subsystem with 16-bit conversion. Its channel configuration can be selected as 16 single-ended inputs or 8 differential inputs, with channel configuration controlled in software. This flexibility allows engineers to match the measurement arrangement to the available sensor signals and grounding scheme.
The module supports multiple bipolar and unipolar voltage ranges, including ±10 V, ±5 V, 0–10 V, ±2.5 V, and smaller ranges for lower-amplitude signals. Selecting an appropriate range helps use the converter’s available resolution effectively. The maximum guaranteed sampling rate is 333 kS/s; actual system throughput depends on acquisition configuration, channel scanning, and data-transfer requirements.
Each analog input must remain within the documented working-voltage limits. Signals outside the permitted range can affect measurement integrity or damage the hardware, so external signal conditioning may be necessary for sensors with incompatible voltage levels or grounding arrangements.
Analog Output and Signal Generation
Two 16-bit analog output channels support voltage generation with a maximum update rate of 333 kS/s. The output range can be configured for bipolar or unipolar operation, including ±10 V and 0–10 V, or referenced to the external analog-output reference input.
The analog outputs can support stimulus generation, voltage control signals, and measurement-system excitation where the connected equipment accepts the selected voltage range. Their maximum current drive is ±5 mA, so loads requiring higher current need an appropriate external driver. The output subsystem also provides short-circuit protection to ground.
Digital I/O and Timing
Eight digital I/O channels support 5 V TTL/CMOS-compatible signaling. These channels can exchange digital states with compatible external circuits, subject to the module’s electrical limits and software configuration.
Two 24-bit up/down counter/timers support event counting and timing operations. The module also includes a frequency scaler. External source selection and trigger routing provide additional flexibility when synchronizing measurements with digital events or other acquisition activities.
The PXI-6052E supports DMA transfers, interrupts, and programmed I/O for applicable data paths. The choice of transfer method affects host integration and data-handling design, particularly in applications involving continuous acquisition or synchronized analog and timing operations.

PXI-6052E

PXI-6052E
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| System architecture | PXI | Install in a compatible PXI chassis and confirm the chassis configuration before integration. |
| Power | +5 VDC ±5%, 1.3 A | Account for the module’s current demand when planning chassis power capacity. |
| I/O connection | 68-pin male SCSI-II-type connector | Select a compatible cable and terminal accessory for the intended signal connections. |
| Analog input configuration | 16 single-ended or 8 differential channels | Configure the measurement mode and grounding arrangement for the application. |
| Analog output | Two voltage output channels | Confirm voltage range, load impedance, and current requirements. |
| Digital signaling | 5 V TTL/CMOS | Verify external logic levels and current requirements before connecting digital equipment. |
| Data transfer | DMA, interrupts, and programmed I/O | Choose the transfer method according to the acquisition architecture and application software. |
| Signal conditioning | SCC or SCXI conditioning can extend measurement capabilities | Select conditioning hardware appropriate to the sensor signal and the intended configuration. |
Dimensions, Mounting & Connection Notes
- Module dimensions: 160 × 100 mm, excluding connectors.
- Module weight: 206 g.
- I/O connector: 68-pin male SCSI-II-type connector.
- Installation environment: 0 to 55 °C operating temperature and 10–90% relative humidity, noncondensing.
- Maximum working voltage: 11 V channel-to-earth and 11 V channel-to-channel, Installation Category I.
- Cable shielding: Shielded cabling is required for the documented EMC compliance conditions.
Before wiring the module, review the terminal assignments and electrical limits for each signal type. In particular, distinguish analog input grounds, analog output reference connections, digital grounds, and programmable function interface (PFI) terminals. Do not assume that every connector pin is a general-purpose digital input or output.
FAQ
What is the NI PXI-6052E?
The NI PXI-6052E is an E Series multifunction data acquisition module combining analog input, analog output, digital I/O, and counter/timer functions in a PXI measurement system.
How many analog input channels does the PXI-6052E provide?
It supports 16 single-ended analog input channels or 8 differential analog input channels, selectable through software configuration.
What is the maximum analog input sampling rate?
The specified maximum guaranteed analog input sampling rate is 333 kS/s. The achievable rate for a particular application depends on its channel configuration and acquisition requirements.
What analog output capabilities does the module provide?
The module has two 16-bit voltage output channels, each supporting a maximum update rate of 333 kS/s. Available output configurations include ±10 V and 0–10 V, along with external-reference-based ranges.
What digital and timing functions are available?
The PXI-6052E provides eight 5 V TTL/CMOS-compatible digital I/O channels, two 24-bit up/down counter/timers, and one frequency scaler.
What connector does the PXI-6052E use?
It uses a 68-pin male SCSI-II-type I/O connector. Cable and terminal accessory selection should account for the required signal assignments and conditioning configuration.
What power does the module require?
The module requires +5 VDC ±5% at 1.3 A. The PXI chassis must have sufficient power capacity for the module and the other installed hardware.
What should engineers check before integrating the module?
Confirm PXI chassis fit, power capacity, connector and cable compatibility, signal voltage limits, grounding, acquisition configuration, and driver support for the intended host operating system and application software.
Documented Performance Data
| Metric | Value | Condition |
|---|---|---|
| Analog input resolution | 16 bits | Analog-to-digital conversion |
| Maximum analog input sampling rate | 333 kS/s | Guaranteed maximum |
| Analog output resolution | 16 bits | Digital-to-analog conversion |
| Maximum analog output update rate | 333 kS/s | Analog voltage generation |
| Counter/timer resolution | 24 bits | Two up/down counter/timers |
| Maximum external counter/timer source frequency | 20 MHz | Counter/timer input |
| Analog input full-scale step settling time | 3 µs maximum to ±6 LSB | Source impedance below 1 kΩ |
| Analog output full-scale step settling time | 3.5 µs to ±1 LSB accuracy | Analog output subsystem |

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626