NI SCXI-1300 General-Purpose Terminal Block

The NI SCXI-1300 is a general-purpose front-mount terminal block that provides convenient screw-terminal connections for 32-channel SCXI modules. It includes an onboard cold-junction temperature sensor for thermocouple measurements and attaches directly to the front of compatible modules via a 96-pin DIN connector.

Categories: , , , , Brand:

Description

Core Product Summary

The NI SCXI-1300 is a general-purpose front-mount terminal block that provides convenient screw-terminal connections for 32-channel SCXI modules. It includes an onboard cold-junction temperature sensor for thermocouple measurements and attaches directly to the front of compatible modules via a 96-pin DIN connector.

The terminal block offers 72 screw terminals, including 32 pairs for differential analog inputs, chassis-ground connections, a safety-ground solder lug, and additional terminals for module OUTPUT, AOREF, and SCXIbus GUARD signals. It is designed for use with the SCXI-1100, SCXI-1102 series, SCXI-1104 series, SCXI-1181, and SCXI-1181K modules.

Key Technical Specifications

Parameter Specification
Product type General-purpose front-mount terminal block
Compatible modules SCXI-1100, SCXI-1102/B/C, SCXI-1104/C, SCXI-1181, SCXI-1181K
Number of screw terminals 72
Differential input pairs 32
Cold-junction sensor type Integrated circuit (LM35CAZ)
Sensor accuracy ±1.3 °C from 0 to 50 °C
Sensor repeatability ±0.5 °C
Sensor output 10 mV/°C (0 to 0.5 V from 0 to 50 °C)
Maximum field wire gauge 26–16 AWG
Connector to module 96-pin DIN
Operating temperature 0 to 50 °C
Storage temperature –20 to 70 °C
Relative humidity 10 to 90 % noncondensing

Detailed Product Overview

The SCXI-1300 serves as the primary field-wiring interface for selected 32-channel SCXI analog input modules. It mounts directly on the front of the module, converting the module’s high-density front connector into easily accessible screw terminals. This arrangement simplifies connection of thermocouples, voltage sources, and other low-level signals while providing the cold-junction compensation reference required for accurate thermocouple measurements.

Thirty-two pairs of screw terminals map directly to the differential input channels of the host module. Two additional terminals connect to the module’s functional chassis ground, and a solder lug provides a dedicated safety chassis ground connection. Extra terminals are available for the module’s analog output, analog output reference, and the SCXIbus GUARD signal, giving system designers flexible grounding and shielding options.

The onboard cold-junction sensor is an integrated-circuit device that produces a linear 10 mV/°C output. When the terminal block is used with a compatible module, the sensor voltage can be read either by multiplexing it with the analog input channels or by routing it to a dedicated DAQ device channel, depending on jumper configuration. Sensor accuracy is specified at ±1.3 °C over the 0 to 50 °C range, which includes both sensor tolerance and residual thermal gradients between the sensor and the screw terminals.

The terminal block is intended for indoor use and accepts field wiring from 26 to 16 AWG. It is fully shielded when properly installed on the host module, helping to maintain signal integrity in typical laboratory and industrial environments.

SCXI-1300

SCXI-1300

SCXI-1300

SCXI-1300

Dimensions, Mounting & Connection Notes

  • Mounting method: Direct front attachment to compatible SCXI modules using the 96-pin DIN connector.
  • Field connections: 72 screw terminals for signal, ground, and auxiliary connections.
  • Wire size: 26–16 AWG.
  • Safety ground: Dedicated solder lug for chassis safety grounding.
  • Environment: Indoor use; operating temperature 0 to 50 °C.

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Host modules SCXI-1100, SCXI-1102/B/C, SCXI-1104/C, SCXI-1181, SCXI-1181K Direct front-mount attachment via 96-pin DIN connector
Cold-junction compensation Onboard IC sensor Can be multiplexed with input channels or routed to a dedicated channel
Field wiring 26–16 AWG Strip insulation and secure under screw terminals
Grounding Functional chassis ground terminals + safety ground solder lug Use safety ground when required by local electrical codes
Mounting Front of compatible SCXI module Secured by the module’s front-panel fasteners

FAQ

What is the NI SCXI-1300?
It is a general-purpose front-mount terminal block that provides screw-terminal access and an onboard cold-junction temperature sensor for selected 32-channel SCXI modules.

Which modules work with the SCXI-1300?
It is compatible with the SCXI-1100, SCXI-1102 series, SCXI-1104 series, SCXI-1181, and SCXI-1181K modules.

Does the SCXI-1300 include cold-junction compensation?
Yes. It contains an integrated-circuit temperature sensor with ±1.3 °C accuracy from 0 to 50 °C and a linear output of 10 mV/°C.

How many screw terminals does it have?
The terminal block provides 72 screw terminals, including 32 pairs for differential inputs plus ground and auxiliary connections.

What wire size is supported?
Field wiring from 26 to 16 AWG is accepted.

How is the terminal block mounted?
It attaches directly to the front of a compatible SCXI module via the 96-pin DIN connector and is secured by the module’s front-panel hardware.