ProSoft MVI56-PDPMV1 ControlLogix PROFIBUS DPV1 Master Module

Parameter Value
Manufacturer ProSoft Technology
Exact model MVI56-PDPMV1
Product type PROFIBUS DPV1 Master communication module
Control platform Rockwell Automation ControlLogix
Chassis compatibility 1756 backplane, single slot
Protocol role PROFIBUS DP Master
Supported slave protocols PROFIBUS DP-V0 and DP-V1
Master specification Complete Master specifications according to IEC 61158
PROFIBUS interface Optically isolated RS-485, DB-9 female connector
Baud rates All standard PROFIBUS rates up to 12 Mbps
Maximum slaves Up to 125 with repeaters

Description

Core Product Summary

The ProSoft MVI56-PDPMV1 is a PROFIBUS DPV1 Master communication module for Rockwell Automation ControlLogix systems. Installed in a 1756 chassis, it acts as a PROFIBUS network scanner and exchanges cyclic and acyclic data between the ControlLogix processor and connected PROFIBUS slave devices.

The module supports PROFIBUS DP-V0 and DP-V1 protocol, all standard baud rates up to 12 Mbps, and up to 125 slaves when repeaters are used. It provides up to 1536 bytes of cyclic input data and 1536 bytes of cyclic output data, extended diagnostics, DPV1 Read/Write services, alarm handling, Sync and Freeze commands, and PROFIdrive 3.1 parameter access. Configuration uses ProSoft Configuration Builder, while ladder logic and Add-On Instructions support data exchange with the ControlLogix processor.

 

Key Technical Specifications

Parameter Value
Manufacturer ProSoft Technology
Exact model MVI56-PDPMV1
Product type PROFIBUS DPV1 Master communication module
Control platform Rockwell Automation ControlLogix
Chassis compatibility 1756 backplane, single slot
Protocol role PROFIBUS DP Master
Supported slave protocols PROFIBUS DP-V0 and DP-V1
Master specification Complete Master specifications according to IEC 61158
PROFIBUS interface Optically isolated RS-485, DB-9 female connector
Baud rates All standard PROFIBUS rates up to 12 Mbps
Maximum slaves Up to 125 with repeaters
Cyclic data capacity Up to 1536 bytes input and 1536 bytes output
Acyclic services DPV1 Class 1 and Class 2 Read/Write
Diagnostic capability Extended diagnostic data and online slave diagnostics
Additional PROFIBUS functions Alarm handling, Sync and Freeze commands, multicast and broadcast telegrams, PROFIdrive 3.1 parameter Read/Write
Configuration software ProSoft Configuration Builder (PCB)
FDT/DTM software PROFIBUS Master transport communication DTM
Backplane current load 800 mA at 5 V DC; 3 mA at 24 V DC
Operating temperature 0 to 60 °C
Storage temperature -40 to 85 °C
Relative humidity 5% to 95%, non-condensing
Configuration/debug port RS-232, RJ-45 connector with supplied DB-9 male adapter
Ethernet routing CIPconnect enabled through a compatible Rockwell Automation Ethernet interface
Marking II 3 G, Ex nA IIC T6 X; 0 °C ≤ Tamb ≤ 60 °C

 

Engineering Selection Highlights

  • The MVI56-PDPMV1 is specifically designed for the Rockwell Automation ControlLogix 1756 platform, so it requires a compatible ControlLogix processor, power supply, and one available chassis slot.
  • Its PROFIBUS DPV1 Master role makes it suitable for applications where the ControlLogix processor must communicate with PROFIBUS DP-V0 or DP-V1 slave devices.
  • The module supports up to 1536 bytes of cyclic input and output data, which should be checked against the combined I/O data requirements of the configured slave devices.
  • The 12 Mbps PROFIBUS interface supports all standard PROFIBUS baud rates, allowing the network speed to be matched to the installed bus topology and device requirements.
  • The module supports DPV1 acyclic Read/Write, alarms, Sync/Freeze, multicast/broadcast telegrams, and PROFIdrive 3.1 parameter access; these functions matter for applications requiring parameter access or diagnostic communication beyond cyclic I/O.
  • LEGACY and FLEX operating modes determine the backplane data arrangement: LEGACY mode uses fixed I/O sizes, while FLEX mode supports configurable I/O block sizes and is available with module firmware version 1.21 or later.
  • Remote-rack installation requires Ethernet/IP or ControlNet access to the processor, so the rack architecture and communication path must be confirmed before deployment.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Control platform Rockwell Automation ControlLogix The module is designed for ControlLogix processors.
Chassis 1756 backplane, single slot One free 1756 chassis slot is required.
Processor connection Recognized as an I/O module; ladder logic transfers data between processor and module Use the supplied sample ladder or Add-On Instruction as the integration basis.
Programming software Rockwell Automation RSLogix 5000 version 2.51 or higher Confirm the installed programming-software version before configuration.
Communication software Rockwell Automation RSLinx Required for communication with the processor.
Module operating mode LEGACY mode for firmware 0.30; LEGACY or FLEX mode for firmware 1.21 or later FLEX mode provides variable backplane I/O block sizes.
LEGACY backplane data Fixed input block of 250 words and output block of 248 words Use this mode where backward compatibility or fixed I/O sizing is required.
FLEX backplane data Input block configurable from 12 to 250 words; output block configurable from 5 to 248 words Use this mode to tailor backplane transfer size to the application.
Remote rack Requires Ethernet/IP or ControlNet access to the processor Confirm the remote-rack communication path before installation.
PROFIBUS network DP-V0 and DP-V1 slave devices Install the applicable GSD files and configure each slave in ProSoft Configuration Builder.
Configuration software ProSoft Configuration Builder Required for module and PROFIBUS-master configuration.
Ethernet configuration CIPconnect enabled; compatible with 1756-ENBT, 1756-EN2T, or similar Ethernet interfaces Used for configuration and communication routing through the Rockwell Ethernet interface.

 

Dimensions, Mounting & Connection Notes

Item Verified information
Mounting Single-slot installation in a compatible 1756 ControlLogix chassis
Rack location Local or remote rack; remote-rack installation requires Ethernet/IP or ControlNet access to the processor
PROFIBUS port Optically isolated RS-485 interface with a 9-pin D-shell female connector
Configuration/debug port RS-232 only, RJ-45 connector; supplied DB-9 male adapter connects to the RS-232 configuration cable
Backplane power 800 mA at 5 V DC; 3 mA at 24 V DC
Operating temperature 0 to 60 °C
Storage temperature -40 to 85 °C
Relative humidity 5% to 95%, non-condensing
Shock 30 g operational; 50 g non-operational
Vibration 5 g from 10 to 150 Hz
Enclosure requirement for ATEX use Mounted in an IP54 enclosure
Battery Rechargeable lithium vanadium pentoxide battery backs up the real-time clock and CMOS; it is not user replaceable

 

Detailed Product Overview

The ProSoft MVI56-PDPMV1 is a PROFIBUS DPV1 Master communication module for the Rockwell Automation ControlLogix platform. It occupies one slot in a compatible 1756 chassis and presents itself to the processor as an I/O module, enabling data transfer between the ControlLogix processor and the PROFIBUS network.

As a PROFIBUS Master, the module scans configured slave devices and transfers cyclic input and output data between the PROFIBUS network and processor data memory. It supports up to 125 slaves when repeaters are used and provides up to 1536 bytes of cyclic input data and 1536 bytes of cyclic output data. These capacities define the upper data volume available for the configured PROFIBUS network and should be checked against the actual slave configuration.

The module supports all standard PROFIBUS baud rates up to 12 Mbps. Its PROFIBUS interface is an optically isolated RS-485 port with a 9-pin D-shell female connector. Approved PROFIBUS cabling and connectors are required, and the installation documentation identifies the need for a small flat-blade screwdriver to secure the PROFIBUS connector to the module.

Beyond cyclic I/O, the MVI56-PDPMV1 supports DPV1 Class 1 and Class 2 acyclic Read/Write services, extended diagnostic data, alarm handling, Sync and Freeze commands, and multicast or broadcast telegrams. It also supports PROFIdrive 3.1 compliant parameter Read/Write operations. These capabilities make the module relevant to PROFIBUS installations that require both routine process-data exchange and parameter-level communication with compatible devices.

Configuration is performed with ProSoft Configuration Builder. The software supports a Master Busview configuration interface, GSD-file import, automatic bus-parameter calculation, project documentation, online slave diagnostics, and monitoring or modification of process and DPV1 acyclic data. A PROFIBUS comDTM is also provided for FDT/DTM-based configuration and diagnostic access.

Integration with the ControlLogix processor uses ladder logic. ProSoft provides sample ladder programs and Add-On Instructions for both LEGACY and FLEX modes. LEGACY mode uses fixed backplane I/O blocks of 250 input words and 248 output words and is compatible with all module firmware versions. FLEX mode, available with module firmware version 1.21 or later, supports configurable backplane I/O block sizes and transfers status, slave diagnostics, and mailbox data through MSG instructions. For ControlLogix firmware version 16 or newer, the supplied Add-On Instruction files can import the required ladder logic, controller tags, and user-defined data types into an application.

The module requires 800 mA at 5 V DC and 3 mA at 24 V DC from the backplane. Its specified operating range is 0 to 60 °C, with storage from -40 to 85 °C and non-condensing relative humidity from 5% to 95%. The module carries the marking II 3 G, Ex nA IIC T6 X, with an ambient-temperature range of 0 to 60 °C. For ATEX-related installation, the documentation requires mounting in an IP54 enclosure and use with ATEX-certified backplanes. The rechargeable lithium vanadium pentoxide battery backs up the real-time clock and CMOS settings but is not user replaceable.

MVI56-PDPMV1

MVI56-PDPMV1

Applications & System Role

The MVI56-PDPMV1 sits between a Rockwell Automation ControlLogix processor and a PROFIBUS DP network. It operates as a PROFIBUS Master, scanning connected slave devices and transferring process input and output data between the PROFIBUS network and processor data memory over the 1756 backplane.

The module supports both cyclic process-data exchange and DPV1 acyclic communication. Cyclic data supports routine control and monitoring of PROFIBUS devices, while DPV1 Read/Write services, alarm handling, and extended diagnostics support parameter access and diagnostic communication with compatible slave devices. Its PROFIdrive 3.1 parameter Read/Write capability is relevant where compatible drives require parameter access through the PROFIBUS network.

 

FAQ

What is the ProSoft MVI56-PDPMV1?
The ProSoft MVI56-PDPMV1 is a PROFIBUS DPV1 Master communication module for Rockwell Automation ControlLogix systems.

Which ControlLogix chassis does the MVI56-PDPMV1 use?
It installs in a single slot of a compatible 1756 ControlLogix chassis.

Which PROFIBUS protocols does the MVI56-PDPMV1 support?
It supports PROFIBUS DP-V0 and DP-V1 slave devices and provides Master functionality according to IEC 61158.

How many PROFIBUS slaves can the MVI56-PDPMV1 support?
The module supports up to 125 slaves when repeaters are used.

How much cyclic data can the MVI56-PDPMV1 exchange?
It supports up to 1536 bytes of cyclic input data and up to 1536 bytes of cyclic output data.

What PROFIBUS speed does the MVI56-PDPMV1 support?
The module supports all standard PROFIBUS baud rates up to 12 Mbps.

What software is required to configure the MVI56-PDPMV1?
ProSoft Configuration Builder is required for module and PROFIBUS-master configuration; RSLogix 5000 version 2.51 or higher and RSLinx are required for the ControlLogix integration.

What is the difference between LEGACY and FLEX modes?
LEGACY mode uses fixed backplane I/O sizes of 250 input words and 248 output words. FLEX mode, available with module firmware version 1.21 or later, supports configurable input and output backplane block sizes and transfers status, slave diagnostics, and mailbox data through MSG instructions.