Sale!

ProSoft MVI56E-MNET Modbus TCP/IP ControlLogix Module

  • Manufacturer: ProSoft Technology
  • Model: MVI56E-MNET
  • Product type: Enhanced Modbus TCP/IP Client/Server Communication Module
  • Host platform: Rockwell Automation ControlLogix
  • Primary function: Enables ControlLogix processors to exchange data with Modbus TCP/IP devices over Ethernet.
  • Communication roles: Modbus TCP/IP client (master) and server (slave)
  • Data memory: User-configurable mapping of up to 5,000 16-bit registers
  • Configuration: ProSoft Configuration Builder, Ethernet-based diagnostics, and supported ControlLogix ladder logic or Add-On Instructions
  • Replacement consideration: The module is backward-compatible with earlier MVI56-MNET versions, but verify the application, configuration, and ladder logic before replacement.
Categories: , , , , SKU: MVI56E-MNET Brand:

Description

Key Technical Specifications

Parameter Specification
Manufacturer ProSoft Technology
Model MVI56E-MNET
Module type Modbus TCP/IP Client/Server Enhanced Communication Module
Host platform Rockwell Automation ControlLogix
Backplane compatibility Single-slot 1756 chassis
Ethernet interface 10/100 Mbps, RJ45, auto-crossover detection
Ethernet port function Configuration, diagnostics, and application communication
Modbus operating modes Client (master) and server (slave)
Data memory Up to 5,000 user-mapped 16-bit registers
Server connections Up to 10 independent connections on TCP port 502 and 10 on port 2000
Client connections One client connection with up to 100 commands
Supported server function codes 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22, 23
Supported client function codes 1, 2, 3, 4, 5, 6, 7, 15, 16
Floating-point data Configurable; supports Enron and Daniel formats
Configuration software ProSoft Configuration Builder (PCB)
Network discovery ProSoft Discovery Service
ControlLogix integration Sample ladder logic and Add-On Instructions
Diagnostics Status LEDs and four-character scrolling alphanumeric display
Backplane current draw 800 mA at 5 VDC; 3 mA at 24 VDC
Operating temperature 0°C to 60°C (32°F to 140°F)
Storage temperature −40°C to 85°C (−40°F to 185°F)
Relative humidity 5–95%, non-condensing
Shock resistance 30 g operational; 50 g non-operational
Vibration resistance 5 g from 10–150 Hz
Configuration backup Nonvolatile CompactFlash personality module

Specifications are based on ProSoft Technology’s published MVI56E-MNET documentation. The separate MVI56E-MNETXT version is designed for harsher environments and has a wider operating-temperature range; do not apply its ratings to the standard MVI56E-MNET.

 

Product Introduction

The ProSoft MVI56E-MNET provides a Modbus TCP/IP interface for Rockwell Automation ControlLogix systems. It allows a ControlLogix processor to exchange data with compatible Modbus TCP/IP devices, including PLCs, instruments, and supervisory systems. Operating as both a client and a server, the module can initiate data requests to remote devices while also responding to requests from other network nodes. Its configurable memory map helps translate Modbus data into values usable by the ControlLogix application.

The module is suited to industrial systems that combine ControlLogix control with Modbus-based equipment. Its Ethernet configuration interface, diagnostic display, and support for ProSoft Configuration Builder simplify commissioning and fault isolation. For replacement projects, the nonvolatile CompactFlash personality module can help preserve module configuration. However, a successful swap still depends on verifying the firmware, configuration, controller logic, IP settings, and actual communication requirements of the installed system.

MVI56E-MNET

MVI56E-MNET

MVI56E-MNET

MVI56E-MNET

Installation & Configuration Guide

Estimated times are planning estimates and vary with system complexity and the quality of existing documentation.

Stage 1 — Verify compatibility and back up configuration

Estimated time: 15–30 minutes

  • Confirm the complete model number is MVI56E-MNET, not MVI56E-MNETXT, MVI56E-MNETC, or MVI56E-MNETR.
  • Check the ControlLogix chassis and slot requirements.
  • Back up the ProSoft configuration, controller program, and relevant ladder logic or Add-On Instructions.
  • Record the existing IP address, subnet settings, Modbus device addresses, and register mapping.

Stage 2 — Install the module and connect Ethernet

Estimated time: 15–30 minutes

  • Place the control system in a safe state and follow site lockout/tagout procedures.
  • Install the module according to the ControlLogix chassis and module installation instructions.
  • Connect the Ethernet cable to the module’s designated RJ45 port.
  • Verify the network segment, cable condition, and IP addressing plan before bringing the interface online.

Stage 3 — Configure Modbus and ControlLogix data exchange

Estimated time: 30–90 minutes

  • Use ProSoft Configuration Builder to configure the module’s network and Modbus parameters.
  • Set up the client command list for remote data reads and writes.
  • Configure server access for systems that need to read from or write to the module.
  • Check register addressing, data types, word order, and floating-point format.
  • Integrate the supplied or approved ladder logic/AOI into the ControlLogix application.

Stage 4 — Commission and verify communication

Estimated time: 30–60 minutes

  • Confirm the module’s status indicators and diagnostic display show normal operation.
  • Verify Ethernet connectivity and confirm the configured Modbus devices are reachable.
  • Test representative read and write commands, including boundary values where appropriate.
  • Check communication counters, error information, and the mapped data in ControlLogix tags.
  • Save the final configuration and document the validated settings before returning the system to normal service.

Commissioning caution: Register offsets, data types, and write permissions must match the target Modbus device. A successful Ethernet connection alone does not prove that process data is mapped correctly.

 

Frequently Asked Questions

Q1: What is the ProSoft MVI56E-MNET used for?

It connects Rockwell Automation ControlLogix processors with Modbus TCP/IP-compatible devices over Ethernet. It supports both client-initiated requests and server responses.

Q2: Can the MVI56E-MNET operate as both a Modbus client and server?

Yes. It supports client and server functionality. Its client supports one connection with up to 100 commands, while server connections are supported on TCP ports 502 and 2000.

Q3: How much data can the module map?

The module supports user-defined data mapping of up to 5,000 16-bit registers. The usable mapping and update behavior depend on the application configuration and ControlLogix data-transfer implementation.

Q4: Is the MVI56E-MNET compatible with the older MVI56-MNET?

ProSoft documents backward compatibility with previous MVI56-MNET versions. Before replacing a module, compare the existing configuration, firmware, ladder logic, and communication behavior. Backward compatibility should not be treated as a guarantee that every application can be transferred without testing.

Q5: What is the difference between MVI56E-MNET and MVI56E-MNETXT?

Both provide the same core Modbus TCP/IP functionality. The standard MVI56E-MNET is rated for 0–60°C operation, while the MVI56E-MNETXT is designed for the Logix-XT platform, has conformal coating, and is rated for −25°C to 70°C operation.

Q6: What software is required for configuration?

ProSoft Configuration Builder is the documented configuration tool. ProSoft Discovery Service can help locate the module on the network and assign a temporary IP address. ControlLogix ladder logic or supported Add-On Instructions are used for data exchange with the processor.

Q7: What should be checked before ordering a replacement?

Verify the exact model suffix, physical condition, CompactFlash configuration media, Ethernet requirements, and the availability of the existing project files. Confirm that the replacement supports the required Modbus commands and data mapping. Current stock, warranty, firmware, and included accessories should be confirmed with the seller.