Description
Core Product Summary
The QTERM-K65 is a panel-mount graphical operator interface terminal originally manufactured by QSI Corporation and now supported under the Beijer Electronics QTERM product family. It combines a supertwist 240 x 128 pixel monochrome LCD, a resistive touch screen, and eight programmable external keys in a polymer housing with NEMA-4 front sealing, providing a compact operator interface for industrial machines and control panels.
Integration is serial-based and deliberately simple: the terminal is available with an EIA-232 or EIA-422 interface, plus a 5-volt buffered interface option and an auxiliary serial port, and it operates from a 9 to 32 VDC supply at low current draw (75 mA typical at 12 VDC with lighting off, 375 mA with lighting on). Screen content is built from predefined objects — text, boxes, lines, gauges, bitmaps, animation, fonts, VT-52 terminal emulation, and touch/key objects — using the object-based Visual Terminal Protocol (VTP) with FormBuilder software, so graphics can be driven over low-bandwidth serial links. The terminal stores applications in 512 KB of flash memory with 256 KB of RAM, and its temperature sensor with automatic contrast adjustment keeps the lighted display readable across its −20 to 60 °C operating range.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Panel-mount graphical operator interface terminal (HMI/OIT) |
| Display | Supertwist graphic LCD, 240 x 128 pixels, monochrome, lighted |
| Backlight dimming | Software-controllable |
| Touch screen | Resistive |
| External keys | 8 programmable keys |
| User memory | 512 KB flash, 256 KB RAM |
| Communication interfaces | EIA-232 or EIA-422; 5-volt buffered interface; auxiliary serial port |
| Programming | Object-based Visual Terminal Protocol (VTP) via FormBuilder software; objects include line, text, box, key, bitmap, gauge, animation, font, VT-52 terminal, and system (hardware) objects |
| Supply voltage | 9 to 32 VDC |
| Power consumption | 75 mA @ 12 VDC typical (lighting off); 375 mA @ 12 VDC typical (lighting on) |
| Mechanical size | 215 x 161 x 50 mm |
| Panel cut-out | 199 x 145 mm |
| Housing material | Polymer |
| Weight | 1.8 kg |
| Front sealing | NEMA-4 |
| Operating temperature | −20 to 60 °C |
| Storage temperature | −30 to 60 °C |
| Humidity | 0 to 95%, non-condensing |
| Shock | 20 g, 3 ms, any axis |
| Vibration | 5 to 5,000 Hz, 4 g RMS |
| Certifications | FCC, CE |
Detailed Product Overview
The QTERM-K65 was designed as a machine-level operator interface where an industrial PC or full graphical panel is unnecessary. Its supertwist 240 x 128 pixel monochrome LCD is large enough for gauges, bar-graph trends, and multi-line status text, while the resistive touch screen lets application designers place touch keys on or around the display, complemented by eight physical programmable keys for gloved-hand or high-frequency operator actions. Backlight level and contrast are both software-controllable, and a built-in temperature sensor drives automatic contrast adjustment so the display stays readable as ambient conditions change.
What distinguishes this terminal technically is its programming model. Instead of downloading a compiled runtime application, the host controller drives the display through Visual Terminal Protocol (VTP), an object-oriented command set managed with FormBuilder software. The programmer creates objects — text, lines, boxes, gauges, bitmaps, animation, fonts, touch keys, and physical key objects — sets their attributes, and enables them with short serial commands. The terminal, not the host, renders and refreshes the objects, so a running application generates very little serial traffic and works well over low-bandwidth links. A VT-52 emulation object also allows the terminal to behave as a conventional character terminal when needed, and a system (hardware) object exposes functions such as backlight and contrast control, key beep, touch screen calibration, firmware version query, and firmware upgrade over the serial interface.
Hardware integration focuses on the serial connection and the panel cut-out. The terminal is ordered with an EIA-232 interface for short host connections or an EIA-422 interface for longer distances and electrically noisy environments; a 5-volt buffered interface option and an auxiliary serial port expand connectivity to additional devices. Power is drawn from a 9 to 32 VDC supply, allowing operation from common 12 V or 24 V control power. Object configurations can be written to the terminal’s ROM so screens are restored at power-up without host intervention.
Mechanically, the polymer-housed unit mounts through a 199 x 145 mm panel cut-out and seals to NEMA-4 at the front, allowing installation in locations subject to washdown conditions. The electronics tolerate −20 to 60 °C operation, 20 g shock, and 4 g RMS vibration from 5 to 5,000 Hz, and an onboard temperature sensor and speaker support contrast compensation and audible key feedback in the final application.

QTERM-K65

QTERM-K65
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host connection | EIA-232 or EIA-422 serial interface | EIA-422 suits longer cable runs and noisier electrical environments; connection procedures and interface wiring are given in the terminal’s user manual |
| Additional interfaces | 5-volt buffered interface; auxiliary serial port | Auxiliary port parameters are set and strings sent through auxiliary-port VTP commands |
| Programming software | Visual Terminal Protocol (VTP) with FormBuilder software | Objects are created, configured, and stored via serial commands; object configurations can be written to ROM for power-up restoration |
| Firmware updates | Firmware upgrade over the serial interface | Performed through the binary data communication procedure described in the user manual |
| Power supply | 9 to 32 VDC | Typical draw 75 mA at 12 VDC with lighting off, 375 mA with lighting on |
| Panel mounting | Panel cut-out 199 x 145 mm | Front sealing rated NEMA-4 |
| Key legend customization | Keys and logo legend customizable at the factory | Terminals ordered to a configuration worksheet are assembled to the worksheet specification at order receipt |
| Certifications | FCC, CE | FCC compliance as a Class A digital device for commercial/industrial environments |
Dimensions, Mounting & Connection Notes
| Item | Value |
|---|---|
| Overall size | 215 x 161 x 50 mm |
| Panel cut-out | 199 x 145 mm |
| Mounting | Panel-mount, polymer housing |
| Weight | 1.8 kg |
| Supply voltage | 9 to 32 VDC |
| Power consumption | 75 mA @ 12 VDC typical (lighting off); 375 mA @ 12 VDC typical (lighting on) |
| Front sealing | NEMA-4 |
| Operating temperature | −20 to 60 °C |
| Storage temperature | −30 to 60 °C |
| Humidity | 0 to 95%, non-condensing |
| Shock | 20 g, 3 ms, any axis |
| Vibration | 5 to 5,000 Hz, 4 g RMS |
Connection notes: the terminal is available with an EIA-232 or EIA-422 interface; a 5-volt buffered interface and an auxiliary serial port are also supported. Communication lines are connected per the interface specifications and connector pin assignments in the QTERM-K65 user manual. Touch screen calibration, backlight, and contrast are performed through system-object VTP commands, and terminal settings can be written to ROM so the power-on configuration persists. When first powered, the terminal runs a power-on setup routine before communication begins. The display is a lighted monochrome supertwist LCD; backlight dimming is software-controllable for ambient-light matching and power management.
FAQ
What is the QTERM-K65?
The QTERM-K65 is a rugged NEMA-4 panel-mount graphical operator interface terminal from QSI Corporation (supported within the Beijer Electronics QTERM family) featuring a 240 x 128 pixel supertwist LCD, a resistive touch screen, and eight programmable external keys.
How is the QTERM-K65 programmed?
It is programmed with the object-based Visual Terminal Protocol (VTP) using FormBuilder software. The host creates and configures objects such as text, gauges, lines, boxes, bitmaps, animation, fonts, VT-52 terminal emulation, and key objects through serial commands, and the terminal renders them locally to keep serial traffic low.
Which communication interfaces does it support?
It is available with an EIA-232 or EIA-422 serial interface, and also provides a 5-volt buffered interface and an auxiliary serial port that can be configured through auxiliary-port VTP commands.
What are the display capabilities?
The display is a lighted, graphical monochrome supertwist LCD with 240 x 128 pixel resolution, software-controllable backlight dimming, and automatic contrast adjustment driven by a built-in temperature sensor.
What power supply does the QTERM-K65 need?
It operates from a 9 to 32 VDC supply, typically drawing 75 mA at 12 VDC with lighting off and 375 mA at 12 VDC with lighting on.
What panel cut-out does it require?
It mounts through a 199 x 145 mm cut-out; the housing measures 215 x 161 x 50 mm and weighs 1.8 kg, with the front sealed to NEMA-4.
How much memory does it have for applications?
It provides 512 KB of flash memory for program and screen storage and 256 KB of RAM, and completed object configurations can be written to ROM so screens are restored automatically at power-up.
What environmental conditions can it withstand?
It operates from −20 to 60 °C, tolerates 20 g shock (3 ms, any axis) and 4 g RMS vibration from 5 to 5,000 Hz, and accepts 0 to 95% non-condensing humidity, with NEMA-4 front sealing for washdown-rated installations.
Can the key legend be customized?
Yes, the key and logo legend can be customized with a company logo and key layout, and terminals ordered with a configuration worksheet are assembled to that specification at order receipt.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626