Sale!

Rolls-Royce SLIO 02 CANman Serial I/O Node Module

Parameter Specification
Product type Distributed serial I/O node
Model SLIO 02
System CANman Controller Network
Network Local CAN bus / S-Bus
I/O functions Digital inputs, digital outputs, analog inputs, and other channels (configuration differs from SLIO 01)
Firmware Application-independent

Description

Core Product Summary

The Rolls-Royce SLIO 02 is a distributed input/output node module for the CANman Controller Network used in Rolls-Royce Marine automation systems. It connects to the local CAN bus (S-Bus) and provides the interface between field devices and the central control nodes (CCN).

The SLIO 02 is the counterpart to the SLIO 01. The two modules differ primarily in their I/O channel configuration; minor software differences also exist. Like the SLIO 01, the SLIO 02 uses application-independent firmware, so its software does not need to be changed when the application code on the CCN nodes is updated. It is used in marine propulsion control, thruster systems, engine monitoring and related shipboard automation.

Key Technical Specifications

Parameter Specification
Product type Distributed serial I/O node
Model SLIO 02
System CANman Controller Network
Network Local CAN bus / S-Bus
I/O functions Digital inputs, digital outputs, analog inputs, and other channels (configuration differs from SLIO 01)
Firmware Application-independent
Typical supply 24 V DC (marine standard)
Mounting Cabinet / chassis mount
Related module SLIO 01 (different I/O configuration)

Engineering Selection Highlights

  • Serves as a remote I/O node on the CANman S-Bus, reducing individual field wiring.
  • I/O channel mix differs from the SLIO 01, allowing the appropriate variant to be selected for each signal requirement.
  • Application-independent firmware simplifies software maintenance across the fleet.
  • Designed for the marine environment (vibration, temperature and humidity typical of engine rooms and technical spaces).
  • Used alongside SLIO 01 modules in the same CANman network.
  • Common spare part for existing Rolls-Royce / Ulstein CANman installations.

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Control network CANman Controller Network (S-Bus) Must be used with compatible CCN nodes
Related modules SLIO 01, CCN control nodes Choose SLIO 01 or SLIO 02 according to required I/O mix
Field devices Sensors, switches, actuators, control levers Wired to the SLIO 02 terminals
Power supply 24 V DC marine supply Follow vessel power distribution practices
Software CANman application running on CCN SLIO firmware remains unchanged when CCN application is updated
Classification Marine-grade design Confirm compliance with applicable class rules for the installation

Dimensions, Mounting & Connection Notes

The SLIO 02 is a compact cabinet-mounted module installed in control cabinets or technical spaces. It connects to the S-Bus network and to field wiring. Power is taken from the vessel’s 24 V DC system. Exact mechanical dimensions, terminal assignments and addressing details are defined in the original Rolls-Royce / Ulstein CANman documentation. Correct CAN-bus termination and node addressing are required for reliable operation.

SLIO 02

SLIO 02

SLIO 02

SLIO 02

Detailed Product Overview

The Rolls-Royce SLIO 02 is the second of the two main serial-link I/O node types used in the CANman Controller Network. In this architecture, central control nodes (CCN) execute the application software, while SLIO nodes handle localized input and output.

The primary difference between the SLIO 01 and SLIO 02 lies in the mix of I/O channels provided. Both modules support digital and analog signals and connect to the same local CAN bus (S-Bus). Minor software differences also exist between the two types. Selection of SLIO 01 or SLIO 02 is determined by the specific signal requirements of each location in the system.

A defining characteristic of both SLIO modules is that their firmware is application-independent. When the control application running on the CCN nodes is modified or updated, the SLIO software remains the same. This design simplifies maintenance and reduces the risk associated with software changes across multiple vessels.

The SLIO 02 is engineered for the marine environment and is found on commercial ships, offshore vessels and other craft equipped with Rolls-Royce / Ulstein CANman-based propulsion and automation systems. Today it is primarily obtained as a spare or replacement part for existing installations.

When replacing an SLIO 02, the correct variant, network address and field wiring must match the original configuration to ensure proper system behaviour.

Applications & System Role

The SLIO 02 functions as a distributed I/O interface in Rolls-Royce Marine CANman automation systems. Typical applications include:

  • Propulsion and thruster control
  • Steering gear and azimuth thruster interfaces
  • Engine and auxiliary system monitoring
  • Control-lever and joystick signal acquisition
  • General shipboard automation I/O

It collects field signals and exchanges data with the central CCN nodes over the S-Bus, supporting the modular architecture of the CANman system.

FAQ

What is the Rolls-Royce SLIO 02?
It is a distributed serial I/O node module for the CANman Controller Network used in Rolls-Royce Marine automation systems.

How does it differ from the SLIO 01?
The main difference is the I/O channel configuration. There are also minor software differences.

What network does it use?
The local CAN bus, also called the S-Bus, within the CANman system.

Is the firmware application-specific?
No. The SLIO firmware is application-independent and does not change when the CCN application software is updated.

Where is the SLIO 02 typically used?
In marine propulsion control, thruster systems, engine monitoring and related shipboard automation on vessels equipped with the CANman system.

Can SLIO 01 and SLIO 02 be mixed on the same network?
Yes. Both types operate on the same S-Bus and are selected according to the required I/O mix at each location.