Stucke Elektronik SYMAP-ECG Multifunction Protection Unit

The Stucke Elektronik SYMAP-ECG is a compact, digital multifunction protection and control relay designed for electrical power generation, marine switchboards, and industrial power distribution systems. Manufactured by Stucke Elektronik, this processor-based unit integrates generator protection, voltage and frequency monitoring, and control functions into a single panel-mounted device.

Categories: , , , , SKU: SYMAP-ECG Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Stucke Elektronik SYMAP-ECG is a compact, digital multifunction protection and control relay designed for electrical power generation, marine switchboards, and industrial power distribution systems. Manufactured by Stucke Elektronik, this processor-based unit integrates generator protection, voltage and frequency monitoring, and control functions into a single panel-mounted device.

The SYMAP-ECG continuously evaluates three-phase current and voltage inputs from electrical systems to safeguard generators, transformers, and switchgear against electrical faults. It features programmable digital protection algorithms, integrated LCD display/keypad interface for local parameterization, flexible I/O channels, and serial communication capabilities (such as Modbus or CANbus) for integration into supervisory control and data acquisition (SCADA) systems or power management architectures.

 

Key Technical Specifications

Parameter Specification
Product Type Digital Multifunction Protection & Control Relay
Manufacturer Stucke Elektronik
Model Series SYMAP Series (Model SYMAP-ECG)
Auxiliary Control Voltage 24 V AC/DC nominal (application variant dependent)
Current Transformer (CT) Inputs 1 A or 5 A secondary rating
Voltage Transformer (PT) Inputs Up to 400 V nominal sensing input
Protection Functions Overcurrent, short-circuit, over/undervoltage, over/underfrequency, reverse power
Display & Interface Front-panel graphic/LCD screen with navigation keys
Enclosure / Mounting Flush panel-mount housing with front-panel IP protection

 

Detailed Product Overview

The Stucke SYMAP-ECG operates as an intelligent protection and control unit engineered to maintain power system stability in marine vessels, offshore installations, and land-based power plants. By consolidating multiple discrete protective functions—such as directional overcurrent, reverse power, phase unbalance, and frequency protection—into one module, it reduces panel wiring complexity and panel cutout requirements.

The unit digitizes incoming analog signals from current and potential transformers via high-precision internal converters. Microprocessor algorithms process these signals against user-configured trip curves and timing delays. Upon detecting an out-of-spec condition or fault state, the device triggers program-assigned output relays to trip primary circuit breakers or initiate alarm sequences.

Physical construction features a rugged front fascia designed for switchboard panel cutouts. Rear terminals accommodate CT/PT wiring, power supply leads, binary inputs, trip output contacts, and communication bus connections.

 

Engineering Selection Highlights

  • Multifunction Protection Integration: Combines generator protection, voltage monitoring, and frequency supervision within a single hardware platform.
  • Flexible Field Measurement: Accepts standard 1 A / 5 A CT inputs and up to 400 V PT secondary voltages for direct measurement.
  • SCADA Interfacing: Integrated serial bus communication protocols enable remote telemetry, status reporting, and event logging.
  • Programmable Logic & I/O: Configurable binary inputs and relay outputs allow custom interlocking and breaker control sequences.
  • Compact Switchboard Fit: Standard panel-mount form factor minimizes switchgear footprint and simplifies wiring.
SYMAP-ECG

SYMAP-ECG

SYMAP-ECG

SYMAP-ECG

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Power Supply 24 V AC/DC Auxiliary Supply Requires stable auxiliary control voltage for internal logic
Current Inputs Standard 1 A or 5 A CT Secondaries CT secondary wiring must be securely terminated to prevent open-circuit high voltages
Voltage Inputs Standard PT Secondaries (up to 400 V AC) Direct or transformer-coupled mains voltage monitoring
Serial Communication RS-485 / CANbus interface (model option) Requires proper bus termination resistors at line ends

 

Dimensions, Mounting & Connection Notes

  • Mounting Method: Flush-mount device intended for switchboard or control cabinet door cutouts.
  • Terminal Connections: Rear-mounted screw terminal blocks for current, voltage, auxiliary power, and control I/O wiring.
  • CT Safety Precaution: Current transformer secondary circuits must be shorted prior to disconnecting terminal blocks during maintenance.
  • Grounding Practice: Ensure the metal chassis enclosure ground point is securely bonded to the main switchboard ground bus.

 

FAQ

  • What is the Stucke SYMAP-ECG?

    It is a digital multifunction protection relay designed for power generation, generator protection, and switchboard automation.

  • Who manufactures the SYMAP-ECG?

    The unit is manufactured by Stucke Elektronik.

  • What protective functions does the SYMAP-ECG offer?

    It typically includes overcurrent, short-circuit, over/undervoltage, over/underfrequency, and reverse power protection functions.

  • What auxiliary supply voltage does it require?

    Standard variants operate on a nominal 24 V AC/DC auxiliary control supply.

 

Verification & Troubleshooting Notes

  • CT Secondary Verification: Verify that current transformer ratios and secondary ratings (1 A or 5 A) configured in software match the installed physical CTs.
  • Phase Sequence Alignment: Check that three-phase voltage and current inputs maintain correct phase rotation to prevent false reverse power or directional overcurrent trips.
  • Trip Contact Commissioning: Test relay trip output contacts independently before energizing primary high-voltage circuits.