3. Key Technical Specifications
- Dynamic signal inputs: 4 independent, fully programmable channels
- Accepted sensor types: Acceleration, velocity, displacement (proximity probes)
- Tachometer (speed) inputs: 2 channels (proximity, magnetic pickup, or TTL)
- On-board processing: Relative & absolute vibration, Smax, eccentricity, thrust position, housing expansion, dynamic pressure
- Frequency range: DC to 60 kHz (–3 dB)
- Input voltage range: DC 0 to ±20 V; AC ±10 V max
- Common-mode voltage range: –50 V to +50 V
- CMRR: >60 dB at 50 Hz
- Crosstalk: –72 dB
- Input impedance: 200 kΩ
- Front-panel features: Buffered BNC connectors for raw signals; status LEDs for errors, OK system, and alarms
- Pairing requirement: Works with corresponding IOC4T input/output card
- Versions available: Standard, separate-circuits, and safety (SIL) versions
- Form factor: Hot-swappable VM600 rack card
4. Product Introduction
The Vibro-Meter MPC4 (part number 200-510-076-114) is the core machinery protection card in the VM600 series. It simultaneously processes up to four dynamic sensor signals and two speed channels, delivering real-time multi-parameter measurements for critical rotating equipment.
This card is widely used on steam and gas turbines, compressors, and other high-value machinery. It provides programmable protection for vibration, position, and related parameters while offering buffered front-panel access and clear status indication for reliable operation in rack-based VM600 systems.
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| No valid measurement or “Not OK” status | Sensor/cable fault or wrong channel configuration | ✅ High | Check gap voltage / sensor power and front-panel LEDs | Verify sensor wiring and channel settings; replace card if hardware fault confirmed |
| Processing or hardware error LED illuminated | Internal fault or configuration mismatch | ✅ High | Record exact LED pattern and system diagnostics | Reseat card; reload configuration; replace if error persists |
| Missing or unstable speed signal | Tachometer sensor or wiring issue | ✅ High | Verify speed signal at BNC or terminals | Check sensor type, wiring, and configuration |
| Alarms trigger incorrectly | Incorrect setpoints, filtering, or time delay | ✅ Medium | Review Alert/Danger levels and hysteresis settings | Adjust setpoints and filtering to match the application |
| No communication with rack or IOC4T | Backplane contact or pairing problem | ✅ High | Confirm IOC4T is present and properly seated | Reseat both cards; verify rack power and backplane |
| Abnormal signal on front-panel BNC | Sensor chain or input circuit fault | ✅ Medium | Scope the raw signal at the BNC connector | Isolate to sensor or replace the MPC4 |
If the issue cannot be resolved, photograph the card (labels and LEDs), note the full part number and revision, and contact technical support with system details.

MPC4 200-510-076-114

MPC4 200-510-076-114
6. Frequently Asked Questions (FAQ)
Q: What does the MPC4 200-510-076-114 do?
A: It is the main machinery protection card in the VM600 system. It monitors up to four dynamic signals and two speed inputs for real-time protection of rotating machinery.
Q: Which sensors are supported?
A: Dynamic channels accept accelerometers, velocity sensors, and proximity (eddy-current) probes. Tachometer channels support proximity, magnetic pickup, or TTL signals.
Q: Does the MPC4 work by itself?
A: No. It must be paired with a corresponding IOC4T input/output card in a VM600 rack.
Q: Is the card hot-swappable?
A: Yes. The MPC4 is designed for hot-swap replacement in a powered VM600 rack (follow proper safety procedures).
Q: Are there different versions of this card?
A: Yes. Standard, separate-circuits, and safety (SIL) versions exist. Confirm the exact version required for your system, especially for functional safety applications.
Q: Can it measure both vibration and axial position?
A: Yes. The programmable channels support relative/absolute vibration, thrust position, eccentricity, Smax, and related parameters.
Q: What condition and warranty do you offer?
A: We supply New Original / New Surplus stock. Units are inspected for basic functionality. Standard coverage is a 1-year warranty against defects. Always provide the complete part number 200-510-076-114 (plus any revision or SIL marking) when ordering or requesting support.

WhatsApp: +86 16626708626