Sale!

Vibro-Meter VM600 IOC16T 16-Channel Input/Output Interface Card

The Vibro-Meter VM600 IOC16T is a 16-channel input/output interface card designed for the VM600 series machinery condition monitoring systems. It serves as the rear-mounted signal termination and conditioning module, pairing directly with a front-mounted CMC16 condition monitoring processor card to form a complete monitoring channel pair.

Categories: , , , , SKU: VM600 IOC16T Brand:

Description

Core Product Summary

The Vibro-Meter VM600 IOC16T is a 16-channel input/output interface card designed for the VM600 series machinery condition monitoring systems. It serves as the rear-mounted signal termination and conditioning module, pairing directly with a front-mounted CMC16 condition monitoring processor card to form a complete monitoring channel pair.

This module provides dedicated termination points for dynamic vibration sensors, quasi-static signals, and tachometer inputs. It routes these analog signals to the paired processor card while simultaneously making them available to other modules in the same chassis via the proprietary VM600 Raw Bus and Tacho Bus. The IOC16T is engineered for integration into standard 19-inch, 6U VM600 system racks, relying on the rack backplane for power and internal communication.

 

Key Technical Specifications

Parameter Specification
Product Family Vibro-Meter VM600 Series
Module Type 16-Channel Input/Output Interface Card
Representative Part Number 200-565-000-013 (varies by configuration)
Compatible Front Card CMC16 Condition Monitoring Card
Mounting Position Rear card cage of VM600 ABE04x (6U) system rack
Channel Capacity 16 dynamic/analog input channels + tachometer inputs
Internal Bus Interfaces VM600 Raw Bus, VM600 Tacho Bus
Power Supply +5 VDC and ±12 VDC (supplied via rack backplane)
Connector Type Removable plug-in terminal blocks (e.g., 24-pin for dynamic channels, 12-pin for tachometer)
Signal Sharing Supports sharing of raw sensor signals with MPC4 machinery protection cards in the same rack

 

Detailed Product Overview

The Vibro-Meter VM600 IOC16T functions as the critical physical interface layer for the VM600 condition monitoring architecture. In a standard VM600 rack configuration, processing and logic are handled by front-mounted cards, while field wiring and signal termination are managed by corresponding rear-mounted I/O cards. The IOC16T is specifically designed to pair with the CMC16 processor, providing the necessary hardware pathways for 16 independent measurement channels.

A defining feature of the IOC16T is its integration with the VM600 rack’s internal communication buses. Beyond routing signals directly to its paired CMC16 card, the module places raw dynamic and tachometer signals onto the VM600 Raw Bus and Tacho Bus. This architecture allows a single set of field sensors to be monitored simultaneously by both the condition monitoring system (CMS) and a machinery protection system (MPS), such as an MPC4 card, without requiring external signal splitters or duplicate wiring.

The module accepts a variety of appropriately conditioned analog signals, including those from piezoelectric accelerometers, velocity sensors, and eddy-current proximity probes, as well as tachometer pulses for speed and phase reference. Protection against electromagnetic interference (EMI) and signal surges is built into the input conditioning circuitry to ensure signal integrity in heavy industrial environments. Configuration of channel parameters, such as sensor type and scaling, is managed via the system software through the paired front-end processor.

VM600 IOC16T

VM600 IOC16T

VM600 IOC16T

VM600 IOC16T

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Required Companion Module CMC16 Condition Monitoring Card Must be installed in the corresponding front slot (slots 3 to 14) of the same rack.
Supported Rack System VM600 ABE04x (6U) System Rack Installs in the rear card cage; requires a compatible backplane.
Internal Signal Routing VM600 Raw Bus and Tacho Bus Enables signal sharing with other cards (e.g., MPC4) in the same chassis.
Power Source VM600 RPS6U Rack Power Supply Draws +5 VDC and ±12 VDC directly from the backplane; no external power required.
Configuration Software VM600 CMS Software or VibroSight Required to configure channel parameters, scaling, and processing modes for the paired CMC16.

 

Dimensions, Mounting & Connection Notes

  • Form Factor: Standard 6U rear rack card, designed to align with the VM600 ABE04x rear card cage.
  • Mounting Method: Installed directly behind the paired CMC16 card. The rear card cage utilizes a slot number coding mechanism to ensure the I/O card is logically mapped to the correct front processor.
  • Connection Type: Removable plug-in connectors. Dynamic channels typically utilize 24-pin connectors, while tachometer inputs use 12-pin connectors.
  • Wiring Recommendation: Manufacturer guidelines specify the use of crimped wire-end ferrules with the recommended plug-in connectors (e.g., B2CF series) to ensure reliable, vibration-resistant terminations.
  • Environmental Limits: Operates within the standard VM600 rack environmental specifications, typically 0 to 65 °C, with proper rack ventilation maintained.

 

FAQ

What is the primary function of the Vibro-Meter VM600 IOC16T?
The IOC16T is a 16-channel input/output interface card that provides physical signal termination and conditioning for the VM600 condition monitoring system, routing sensor data to its paired front-mounted processor.

Which processor card does the IOC16T pair with?
The IOC16T is designed to be installed directly behind a CMC16 condition monitoring card in the rear of a VM600 ABE04x system rack.

Can the IOC16T share sensor data with other cards in the same rack?
Yes. The module outputs raw dynamic and tachometer signals to the VM600 Raw Bus and Tacho Bus, allowing other modules, such as MPC4 machinery protection cards, to monitor the same sensors simultaneously.

Does the IOC16T require an external power supply?
No. The module draws its required +5 VDC and ±12 VDC power directly from the VM600 rack backplane, which is supplied by the rack’s RPS6U power supply unit.

What type of wiring connectors does the IOC16T use?
It utilizes removable plug-in terminal blocks (typically 24-pin for dynamic channels and 12-pin for tachometer inputs). The use of crimped wire-end ferrules is recommended to ensure secure and reliable connections in industrial environments.

+50