Sale!

Yaskawa JAMSC-B2902V PLC Relay Output Module

  • Model: JAMSC-B2902V
  • Brand: Yaskawa
  • Series: MEMOCON-SC PLC
  • Core Function: Relay output switching for PLC-controlled equipment
  • Product Type: PLC relay output module
  • Key Specs: 32-line output configuration; relay outputs; screw-terminal interface
  • Status: Legacy / discontinued model
  • Condition: Verify New Original, New Surplus, or Refurbished condition before purchase

Yaskawa-related equipment listings identify JAMSC-B2902V as a PLC relay-output module, while another industrial automation source identifies the closely related JAMSC-B2902 as a 32-line relay-output module with screw terminals.

Categories: , , , , SKU: JAMSC-B2902V Brand:

Description

Key Technical Specifications

Parameter Value
Manufacturer Yaskawa Electric
Model JAMSC-B2902V
Product Type PLC relay output module
PLC Family MEMOCON-SC
Output Type Relay
I/O Configuration 32-line output
Terminal Type Screw terminals
Application PLC-controlled machine and process outputs
Typical Function Switching external loads from PLC commands
Lifecycle Legacy / discontinued
Mounting MEMOCON-SC PLC system
Related Model JAMSC-B2902

Technical caution: Publicly available references agree that the JAMSC-B2902V is a Yaskawa PLC relay-output module, but they do not provide enough authoritative information to safely state every electrical output rating. Do not infer contact voltage/current ratings from the 32-point designation. Verify the original Yaskawa hardware manual or nameplate before connecting field loads.

A Yaskawa equipment-history listing also associates JAMSC-B2902V with the relay-output category and lists it among legacy Yaskawa PLC components.

 

Product Introduction

The Yaskawa JAMSC-B2902V is a legacy PLC relay output module used with Yaskawa control systems, particularly the MEMOCON-SC platform. Its primary job is to provide relay-based switching outputs between PLC logic and external machine devices. Public references identify the module as a 32-line relay-output configuration.

This is a replacement-oriented part rather than a current-generation I/O product. For an installed MEMOCON-SC system, preserving the exact output configuration and terminal arrangement matters more than selecting a newer-looking module. Verify the load type and electrical ratings before reusing existing field wiring.

JAMSC-B2902V

JAMSC-B2902V

JAMSC-B2902V

JAMSC-B2902V

Installation & Configuration Guide

Stage 1: Pre-Installation Preparation — approximately 10 minutes

  1. Confirm the complete part number: JAMSC-B2902V.
  2. Confirm that the existing PLC system is a compatible Yaskawa MEMOCON-SC installation.
  3. Notify operations and place the controlled equipment in a safe state.
  4. Apply the plant’s lockout/tagout (LOTO) procedure.
  5. Photograph the module face, terminal wiring, module position, and adjacent modules.
  6. Record every connected field-wire terminal.
  7. Prepare:
    • ESD wrist strap
    • Multimeter
    • Screwdrivers
    • Wire labels
    • Smartphone/camera
  8. Obtain the applicable Yaskawa wiring diagram before disconnecting field wiring.

Stage 2: Removing the Old Module — approximately 5–10 minutes

  1. Remove power from the PLC rack according to the system procedure.
  2. Verify that the supply voltage has fallen to a safe level.
  3. Label every field wire.
  4. Photograph the complete terminal arrangement.
  5. Loosen the terminal screws and disconnect the field wiring.
  6. Release the module’s mechanical retention hardware.
  7. Remove the module without forcing the backplane connector.
  8. Inspect the rack connector for contamination, bent contacts, or mechanical damage.

⚠️ Keep the old JAMSC-B2902V available until the replacement has passed the output test.

Stage 3: Installing the New Module — approximately 5–10 minutes

  1. Compare the replacement marking with the original: .
  2. Confirm the module position in the MEMOCON-SC rack.
  3. Use ESD precautions when handling the board.
  4. Insert the module squarely into the rack.
  5. Secure the module using the original mounting mechanism.
  6. Reconnect each field wire according to the photograph and wiring diagram.
  7. Check every terminal for mechanical tightness.
  8. Do not connect a field load until its voltage and current requirements have been checked against the relay contact rating.

Stage 4: Power-On & Testing — approximately 10–15 minutes

  1. Perform a final wiring inspection.
  2. Check for shorts between field conductors and ground.
  3. Restore PLC power.
  4. Check module status indicators, if provided.
  5. Verify that the PLC recognizes the output module without a hardware diagnostic.
  6. Force/test individual outputs using the approved commissioning procedure.
  7. Confirm the corresponding field device operates correctly.
  8. Test each required output group.
  9. Remove all forced states before returning the machine to automatic operation.
  10. Verify interlocks and emergency-stop circuits independently.

⚠️ Do not use a forced PLC output as a substitute for testing the machine’s safety circuit. Relay-output testing should be performed with the controlled equipment in a safe commissioning state.

 

Frequently Asked Questions (FAQ)

What is the Yaskawa ?

It is a PLC relay output module associated with Yaskawa’s legacy MEMOCON-SC control platform. Available references identify it as a 32-line relay-output module.

Is obsolete?

It should be treated as a legacy/discontinued component for procurement purposes. Multiple Yaskawa equipment-history sources list the JAMSC-B2902 family among discontinued or legacy PLC components.

Is the same as JAMSC-B2902?

They are closely related part numbers, and industrial automation listings identify JAMSC-B2902 as an alternate part number for . However, I would still match the exact suffix and physical marking before substitution.

Can I replace it with a modern Yaskawa output module?

Not automatically. This is an older MEMOCON-SC architecture. A modern PLC output module may use a different backplane, addressing scheme, electrical interface, or programming architecture. A direct replacement requires documented hardware compatibility.

Can I hot-swap the ?

Do not assume hot-swapping is permitted. Unless the applicable Yaskawa system manual explicitly specifies energized module replacement for this rack, remove power before replacing the module.

What should I check before buying a replacement?

Check the following against the installed module:

  • Exact model:
  • Output type: Relay
  • Number of output lines
  • Terminal arrangement
  • Rack/module position
  • Field-load voltage
  • Field-load current
  • Existing MEMOCON-SC CPU and rack configuration

The electrical load rating is particularly important because a relay-output module must be matched to the actual field-device voltage and current rather than just the PLC output address.

Why might this part be difficult to source?

The belongs to a legacy Yaskawa PLC platform. Current availability is therefore more likely to involve new old stock, surplus inventory, or tested refurbished units rather than current production stock. One industrial automation supplier currently lists the related JAMSC-B2902 as used/refurbished inventory, reinforcing the need to verify actual condition before purchase.