Description
Core Product Summary
The EPRO PR6424/003-110 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO range, built around the larger 16 mm sensor of the family. It is designed for extremely critical turbomachinery — steam, gas, compressor and hydro machinery, blowers and fans — where it measures radial and axial shaft displacement, shaft position, eccentricity, thrust, differential expansion, valve position and air gaps without contacting the shaft. The 16 mm tip suits large shafts where a wider target area is required.
Per its order code, this variant has an M18x1.5 sleeve thread, a total sensor length of 82.5 mm, an unarmored 5 m cable without an adapter plug, and a Lemo connector at the cable end. Driven by the CON021 converter, the chain delivers a 4 V/mm (101.6 mV/mil) sensitivity with a ±2.0 mm static measuring range and 0 to 1000 µm dynamic range, meeting DIN 45670, ISO 10817-1 and API 670.
Key Technical Specifications
| Parameter | Value |
|---|---|
| System composition | 16 mm eddy current sensor PR6424/003-110 + CON021 signal converter |
| Probe configuration | M18x1.5 sleeve thread, unarmored cable, total sensor length 82.5 mm, no adapter plug, 5 m cable, Lemo end |
| Sensitivity / linearity | 4 V/mm (101.6 mV/mil), linearity error within ±1.5% |
| Static measuring range | ±2.0 mm (0.079 in) |
| Dynamic measuring range | 0 to 1000 µm (0 to 0.039 in) |
| Air gap (center) | approx. 2.7 mm (0.11 in) |
| Long-term drift | < 0.3% |
| Target material (standard) | 42CrMo4 ferromagnetic steel |
| Minimum shaft diameter | ≥ 80 mm |
| Operating temperature range | ‘-35 °C to +150 °C (-31 to +302 °F) |
| Temperature error | < 4% per 100 K (API 670 compliant) |
| Pressure resistance of sensor tip | 10,000 hPa (145 psi) |
| Shock and vibration | 5 g at 60 Hz at 25 °C |
| Materials | Stainless steel case |
| Converter supply voltage | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) |
| Converter frequency response (-3 dB) | 0 to 20,000 Hz |
| Converter rise time | < 15 µs |
| Converter operating temperature | ‘-30 °C to +100 °C |
| Converter protection class | IP20 |
| Standards / approvals | DIN 45670, ISO 10817-1, API 670; rated for explosive areas, Eex ib IIC T6/T4 |
Detailed Product Overview
The PR6424 sits one size class above the widely used 8 mm probes in the EPRO displacement family, and that size difference is the core of its application logic. A 16 mm tip projects a larger electromagnetic field, which requires a larger conductive target to develop properly: the specified performance applies to shafts of at least 80 mm diameter, and the probe is the appropriate choice on large turbomachinery rotors where an 8 mm tip on a very large shaft would still work, but the 16 mm system provides a 4 V/mm sensitivity suited to the larger gaps involved. In exchange for the larger tip, the linear working span is generous — ±2.0 mm static range with a center air gap of approximately 2.7 mm — which supports measurement duties such as differential expansion and valve position that exceed the range of smaller probes.
The measuring physics is the same eddy current principle used across the family: the CON021 converter energizes the probe coil at high frequency, and motion of the conductive shaft surface changes the energy absorbed by eddy currents in the target; the converter demodulates this into a DC gap voltage with the dynamic component superimposed. One channel therefore reads both position and vibration. The converter requires a negative supply from the monitoring rack — either -23 to -32 V for the -4 to -20 V output or -21 to -32 V for the -2 to -18 V output — and its 20 kHz bandwidth with sub-15 µs rise time preserves high-speed dynamic content.
The order code defines the mechanical envelope engineers must respect at installation. The M18x1.5 sleeve thread is substantially larger than the M10x1 thread of the 8 mm family, so holders, locknuts and drill-through dimensions are specific to this series; an installation prepared for a smaller probe cannot accept this sensor. The 82.5 mm total sensor length corresponds to the longer-case variant of the family (Cx = 70 mm), which must be matched to the bearing housing depth so the tip sits at the correct distance from the shaft. The 5 m unarmored cable runs continuously from sensor to Lemo connector without an adapter plug; because the stated sensitivity applies to the complete probe–cable–converter chain, the cable must be routed as supplied and not shortened or extended, and protective conduit should be planned where the routing is mechanically exposed.
Environmental limits differ from the smaller sibling family and should be checked against the machine: the sensor is rated -35 to +150 °C, the temperature error stays below 4% per 100 K in line with API 670, and the sensor tip withstands 10,000 hPa of pressure, which permits installation through bearing housings exposed to oil pressure. The approval basis for hazardous areas is Eex ib IIC T6/T4 intrinsic safety, and the chain meets DIN 45670, ISO 10817-1 and API 670 — the standards commonly referenced in turbine supervision instrumentation specifications. Target conditions remain decisive for accuracy: the 42CrMo4 steel calibration basis and the 80 mm minimum shaft diameter define when the stated linearity applies, and other alloys or magnetized surfaces shift the effective sensitivity.

PR6424003-110+CON021

PR6424003-110+CON021
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor–converter pairing | PR6424/003-110 probe with CON021 eddy current signal converter | Complete transducer system requires converter and cable selected as a matched chain |
| Converter supply | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) | Supplied by the monitoring system |
| Probe connection | Lemo connector at the 5 m cable end mates with the converter input | Cable length is part of the chain calibration; do not modify |
| Mounting thread | M18x1.5 sleeve thread, 82.5 mm total sensor length | Holders and drill-throughs are specific to the 16 mm family |
| Measured target | 42CrMo4 steel, shaft diameter at least 80 mm | Smaller shafts do not meet the specified performance |
| Standards compliance | DIN 45670, ISO 10817-1, API 670 | Relevant for TSI specification conformity |
| Hazardous area | Rated for explosive areas, Eex ib IIC T6/T4 | Installation must follow the intrinsic-safety conditions |
| Monitoring system | Output feeds EPRO MMS series monitoring modules | Output range must match the monitor input channel configuration |
Dimensions, Mounting & Connection Notes
- Sleeve thread: M18x1.5 (3/4″-16 UNF is the alternative family thread), with a total sensor length of 82.5 mm on this order code (Cx = 70 mm).
- The probe is installed facing the shaft surface with the center air gap set at approximately 2.7 mm (0.11 in) during commissioning, inside the ±2.0 mm static range.
- The cable is unarmored over its 5 m length, without an adapter plug, terminating in a Lemo connector.
- Operating temperature range: -35 °C to +150 °C; the sensor tip withstands 10,000 hPa (145 psi) of pressure.
- Shock and vibration capability: 5 g at 60 Hz at 25 °C.
- The CON021 converter is IP20 and must be panel-mounted in a protected cabinet.
FAQ
What is the EPRO PR6424/003-110+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: a 16 mm non-contact displacement sensor with an M18x1.5 thread, 82.5 mm sensor length, unarmored 5 m cable and Lemo termination, paired with the CON021 signal converter.
What is it used for?
It measures static and dynamic shaft displacement on large critical turbomachinery — axial and radial shaft position, eccentricity, shaft vibration, thrust, differential expansion, valve position and air gaps.
How does the 16 mm probe differ from the 8 mm PR6423 series?
It uses a larger tip with a 4 V/mm sensitivity, a ±2.0 mm static range and an approximate 2.7 mm center air gap, and it requires a shaft of at least 80 mm diameter; the M18x1.5 mounting thread is also specific to this family.
What are its key specifications?
Sensitivity 4 V/mm (101.6 mV/mil) with linearity error within ±1.5%, static range ±2.0 mm, dynamic range 0 to 1000 µm, long-term drift below 0.3%, and operating range -35 °C to +150 °C.
What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.
Which standards and approvals apply?
The chain meets DIN 45670, ISO 10817-1 and API 670, and it is rated for explosive areas with Eex ib IIC T6/T4 intrinsic safety.
Can the 5 m cable be shortened or extended?
The stated sensitivity applies to the complete matched probe–cable–converter chain, so the 5 m cable length must be preserved; modifying the cable changes the system calibration.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626