The GE EPSCPE100-ABAC is a standalone central processing unit (CPU) in the PACSystems RSTi-EP industrial automation product line. Designed for compact machine control and distributed automation architectures, this DIN-rail mounted controller executes user logic while serving as the head-end processor for local RSTi-EP slice I/O modules and Ethernet-based field networks.
Built for direct integration with RSTi-EP I/O slices, the EPSCPE100-ABAC provides 1 MB of configurable user memory and communicates over two independent Ethernet networks (three RJ45 ports total), one RS-232 serial interface, and one USB 2.0 host port. It operates on a 24 VDC nominal power input, supports industrial protocols including PROFINET I/O Controller, Modbus TCP, SRTP, and Ethernet Global Data (EGD), and is configured using Proficy Machine Edition software.
Key Technical Specifications
| Parameter | Verified Specification |
| Manufacturer / Brand | GE (PACSystems) |
| Model / Order Number | EPSCPE100-ABAC (CPE100) |
| Product Series | PACSystems RSTi-EP |
| Product Type | Standalone Programmable Automation Controller (PAC) CPU |
| User Memory | 1 MB configurable program and data memory |
| Ethernet Interfaces | 3 × RJ45 (10/100 Mbps): LAN1 (1 port) and LAN2 (2-port integrated switch) |
| Supported Ethernet Protocols | PROFINET I/O Controller, Modbus TCP (Client/Server), SRTP, Ethernet Global Data (EGD), OPC UA Server |
| Serial Interface | 1 × RS-232 (RJ45 connector) |
| USB Interface | 1 × USB 2.0 Host (Type-A) |
| Local I/O Expansion | Direct connection to PACSystems RSTi-EP slice I/O modules (up to 64 modules) |
| Nominal Supply Voltage | 24 VDC (operating range: 18 VDC to 30 VDC) |
| Operating Temperature | -40 °C to +70 °C |
| Mounting Method | 35 mm DIN rail |
| Programming Software | Proficy Machine Edition (PAC Machine Edition) |
Detailed Product Overview
The GE EPSCPE100-ABAC brings PACSystems control execution to a compact, DIN-rail form factor without requiring a traditional backplane chassis. Positioned at the left end of an RSTi-EP station, the controller combines logic execution, network communications, and local I/O bus management inside a single housing.
Its dual-network Ethernet architecture separates control and plant-level traffic. LAN1 provides a dedicated single-port 10/100 Mbps interface typically assigned to supervisory, SCADA, or programming traffic, while LAN2 features an integrated two-port 10/100 Mbps switch suitable for daisy-chained field devices or linear PROFINET I/O topologies. Native support for PROFINET I/O Controller, Modbus TCP, SRTP, EGD, and OPC UA allows the controller to exchange data across heterogeneous plant networks without external protocol gateways.
For local signal acquisition and actuation, the EPSCPE100-ABAC connects directly to RSTi-EP slice I/O modules via its integrated side-bus interface, supporting up to 64 I/O slices on a single station. The 24 VDC input terminal block supplies both the CPU electronics and the internal I/O bus power, simplifying panel wiring in space-constrained enclosures.
The wide operating temperature rating (-40 °C to +70 °C) enables deployment in unconditioned cabinets, outdoor enclosures, and heavy industrial environments where standard commercial temperature ranges are insufficient. Application logic, hardware configuration, and diagnostics are managed through Proficy Machine Edition, allowing engineers to reuse existing PACSystems logic structures across distributed machine skids and remote automation nodes.

EPSCPE100-ABAC
Engineering Selection Highlights
- Chassis-less RSTi-EP architecture → Mounts directly on a 35 mm DIN rail and interfaces with up to 64 RSTi-EP slice I/O modules, eliminating the cost and footprint of a slotted rack or backplane.
- Segregated dual-LAN Ethernet design (3 × RJ45) → Separates plant/HMI communications (LAN1) from deterministic fieldbus traffic on the two-port switched interface (LAN2).
- Multi-protocol Ethernet support → Natively operates as a PROFINET I/O Controller alongside Modbus TCP, SRTP, EGD, and OPC UA, enabling direct integration with existing GE/Emerson controllers and third-party field devices.
- 1 MB user memory allocation → Provides sufficient program and register space for standalone machine control, skid automation, and distributed remote terminal tasks.
- Extended -40 °C to +70 °C operating range → Supports installation in harsh thermal environments without requiring active cabinet cooling or heating within the rated limits.
- Front-accessible USB 2.0 and RS-232 ports → Simplifies local firmware updates, project backup/restore operations, and legacy serial device connections during commissioning.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Local I/O System | PACSystems RSTi-EP Slice I/O Modules | Attaches directly to the right side of the CPU via the RSTi-EP system bus; supports up to 64 modules. |
| Fieldbus / Network Devices | PROFINET I/O Devices, Modbus TCP, SRTP, EGD | Configured over the 10/100 Mbps RJ45 Ethernet ports (LAN1 / LAN2). |
| Engineering Software | Proficy Machine Edition (PAC Machine Edition) | Required for hardware configuration, ladder/structured text programming, and online diagnostics. |
| Power Supply | Regulated 24 VDC (18–30 VDC) | Connects to the integrated front power terminal block to power the CPU and RSTi-EP system bus. |
| Local Storage / Maintenance | Standard USB 2.0 Flash Drive | Used via the front Type-A USB port for firmware updates and project transfer. |
Dimensions, Mounting & Connection Notes
- Mounting Orientation: Mounts horizontally onto a standard 35 mm DIN rail; lock the DIN-rail latch securely before attaching adjacent RSTi-EP I/O slices.
- Power Connections: Accepts 24 VDC (18–30 VDC) via the removable front power connector, with dedicated terminals for system power, field power, and functional earth ground.
- Network & Serial Ports: Uses standard shielded RJ45 connectors for LAN1, LAN2 (2-port switch), and the RS-232 serial port; use shielded twisted-pair cabling to maintain electromagnetic compatibility in industrial panels.
- USB Port: Front-panel USB 2.0 Type-A receptacle intended for temporary service, firmware loading, and data transfer tasks.
- Environmental Limits: Ensure enclosure ambient temperature remains within -40 °C to +70 °C and maintain unobstructed airflow around top and bottom ventilation slots.
FAQ
What is the GE EPSCPE100-ABAC? The GE EPSCPE100-ABAC is a standalone Programmable Automation Controller (PAC) CPU module in the PACSystems RSTi-EP family, designed for DIN-rail machine control and distributed I/O processing.
How much memory does the EPSCPE100-ABAC have? It includes 1 MB of configurable user memory for application logic and process data.
Which communication protocols are supported on the Ethernet ports? The controller supports PROFINET I/O Controller, Modbus TCP, SRTP, Ethernet Global Data (EGD), and OPC UA Server across its three 10/100 Mbps RJ45 Ethernet ports.
How many local I/O modules can connect directly to this CPU? Up to 64 PACSystems RSTi-EP slice I/O modules can be connected directly to the right side of the EPSCPE100-ABAC via the local system bus.
What power supply is required for the EPSCPE100-ABAC? It requires a 24 VDC nominal power source with an allowable operating input range of 18 VDC to 30 VDC.
Which software is used to program and configure the EPSCPE100-ABAC? Configuration, programming, and diagnostics are performed using Proficy Machine Edition (PAC Machine Edition).
Verification & Troubleshooting Notes
- Power & Startup Verification: Confirm that incoming supply voltage at the CPU power terminal measures between 18 VDC and 30 VDC and that the 0 V and functional earth connections are properly landed before energizing.
- Status LED Inspection: Check the front status indicators (
OK,RUN,FAULT, and port link/activity LEDs) during boot-up; a missingOKindication or activeFAULTLED requires connecting Proficy Machine Edition to read the controller fault table. - RSTi-EP Bus Seating: If downstream slice I/O modules fail to communicate or report bus errors, power down the station and verify that all side-bus connectors between the CPU and adjacent I/O slices are fully seated and latched.
- Ethernet Link & IP Verification: Verify physical link LEDs on LAN1 and LAN2; if the controller is unreachable over Ethernet, connect via the USB port or verify the configured IP parameters in Proficy Machine Edition to rule out subnet mismatches or duplicate IP addresses.
- Safety Precaution: Always isolate 24 VDC system and field power before removing or inserting the CPU or attached RSTi-EP I/O modules on the DIN rail.